Intrinsically safe dataline Surge Protector for hazardous area mounting.

Part Number: 86210613119
TSP-P3-48-M-EX/C
TSP-P3-48-M-EX/C
TSP-P3-48-M-EX/C
TSP-P3-48-M-EX/C
TSP-P3-48-M-EX/C

• Intrinsically safe and flameproof follow GB standards • Max discharge current Imax: 20kA • EX certification (CCC) approved • Complies with IEC 61643-21, GB/T 18802.21, GB/T 3836.1, GB/T 3836.4

The TSP range (Type2 or Type2+3) is designed to protect the instruments and apparatus in hazardous area, this surge protector have very low interference for signal transmission, while Citel high duty discharge tube are capable of withstand Imax=20kA impulses. Parallel circuit design with GDT and fast clamping diodes branches provide high surge current capability and low residual voltage. The whole unit is encased in a 316 stainless steel housing for flameproof function, threaded for the common interface used on process transmitters, the transmitter manufacturers can installed directly without involving any additional wiring, conduit modifications. Six prismatic shape of the housing designed for convenient installation even in narrow space.

SPD type
IEC

2+3

Network

RS232, RS485, 4-20mA

Nominal line voltage
Un

24 Vdc

Max. DC operating voltage
Uc

48 Vdc

Max. frequency
f max.

2 MHz

Insertion loss

≤ 0.5 dB

Nominal discharge current
15 x 8/20 µs impulses
In

10 kA(L-PE)

Max. discharge current
max. withstand @ 8/20 µs by pole
Imax

20 kA

Impulse current by pole
max. withstand 10/350µs by pole
Iimp

5 kA(L-PE)

Line inductance (± 10 %)

non

Protection mode(s)

Common/Differential mode

Protection Level
C3 (10/1000μs), 300 applications@10 A, Y-C (Line/Earth)
Up

600 V

Line/Line Nominal discharge current
C2 Category
In L/L

10 kA

IP degree

IP67

Technology

GDT+TVS diode

SPD configuration

3 wires

Connection to Network

Built-in AWG 16# wires(L is 22mm,PE is 19.5mm)

Format

Mounting with threaded interface

Mounting

M20 thread connection

Housing material

316 stainless steel

Operating temperature
Tu

-40/+85°C

Dimensions

See diagram

Standards compliance

IEC 61643-21, GB/T 18802.21, GB/T 3836.1, GB/T 3836.4

Certification

CCC